1 USER MANUAL BNW - 50 Bridge Navigational Watch Alarm System Rev. M00-0481-01

Pagina 2

10 2.2.2 VISUAL INDICATION If not “RESET” during this dormant period (3~12 minutes), visual indication will be initiated for the next 15 seco

Pagina 3 - QUICK USER MANUAL

11 CHAPTER 3 PRODUCT SPECIFICATION 3.1 DISPLAY UNIT (BNW-50) SCREEN SIZE ……………… 4.3 INCH TFT COLOR LCD, 480 X 272 PIXELS POWER CONSUM

Pagina 4 - SIGN DESCRIPTION

12 3.4 ALARM UNIT (BNW-53) POWER CONSUMPTION ……………… max 30mA / unit (24V DC) SIZE ……………… 126x90x30 mm (H x W x D) WEIGHT

Pagina 5

13 3.6 COMPONENTS 3.6.1 BNW-50 SPECIFICATION NO NAME MODEL NAME QUANT REMARK 1 Display unit desktop BNW-50 1 SET Bracket, protection c

Pagina 6

14 CHAPTER 4 BNW-50 (DISPLAY UNIT) - Rated input voltage DC 24V (NOTE) Program version may change without notice for performance improve

Pagina 7

15 System stops operating and goes into sleep mode by pressing this button and entering the password. In order to deactivate the

Pagina 8 - CHAPTER 1 ABOUT BNWAS

16 4.3 OPERATION SCREEN BNW-50’s current operational status appears on the screen. From menu, press ESC then will move to the operati

Pagina 9 - 2.1 OPERATIONAL MODES

17 4.4.1 OPERATION SETUP You can change and save the Operational mode, the dormant period, the delay between the 2nd & 3rd stage al

Pagina 10 - 2.4 EMERGENCY CALL

18 Activated : The dormant period timer will be operated. Deactivated : The dormant period timer will not be operated. AC

Pagina 11

19  The period of 1st stage bridge audible alarm Tone. You can change the Reset unit (BNW-52/52W)’s period of 1st stage bridge audible alar

Pagina 13 - 3.6 COMPONENTS

20 ※ However, if setting by use the additional visual indication and 1st stage bridge audible alarm, The ALARM UNIT A and B will cha

Pagina 14 - - Rated input voltage DC 24V

21  Saving the VDR data by using the SD card (Record VDR data on SD card) After inserting the SD card, by using and , select the “ Record VDR dat

Pagina 15

22 4.5.1 OPERATION SETUP You can change and save the Operational mode, the dormant period, the delay between the 2nd & 3rd stage al

Pagina 16 -  Checking the Password

23 4.5.2 SETUP ALARM UNITS On this menu, you may select the 2nd & 3rd stage remote audible alarm of the each processor unit’s interface termi

Pagina 17 - Operational mode

24  After changing the settings pressMENU, then you will be asked if you wish to save. Press " YES " then to

Pagina 18

25 You must be aware that by using this function, all the settings will initialize.  Self Testing - Refer to 4.4.2 SYSTE

Pagina 19 -  Self Testing

26 4.6 OPERATIONAL DESCRIPTION As shown on the right, "Operational Mode = Manual ON, Dormant period = 3 minutes, the delay between the 2n

Pagina 20 -

27 4.6.3 1ST STAGE BRIDGE AUDIBLE ALARM If not “RESET”, the BNW-50 will additionally sound a 1st stage bridge audible alarm on the bridge 15 secon

Pagina 21 - 4.5 INSTALLATION MENU

28 4.6.6 EMERGENCY CALL BNW-50 has built-in emergency call function. If the EMG button of display unit (BNW-50) is pressed

Pagina 22

29 4.6.7 MALFUNCTION INDICATION BNW-50 provides indication to the following malfunction. If the malfunction is activated, the display

Pagina 23 - 4.5.2 SETUP ALARM UNITS

3 QUICK USER MANUAL NAME [MENU] [ENT] [CHECK] [EMG] [ESC] [RES] [POWER] [DIRECTION] BUTTON MENU EMG ESC RES 1. PASSWORD SETTING ① When

Pagina 24 -  Initialize

30 CHAPTER 5 BNW-51 (PROCESSOR UNIT) 5.1 LED FUNCTION (FRONT) Bridge Navigational Watch Alarm SystemProcessor UnitPOWER ALARMERRORAUTO TIMERB

Pagina 25 -  Check the VDR DATA

31 5.2 POWER AND INTERFACE (BACK) DC FUSE(5A)FUSEINTERFACE110/220VACGND14FUSEAC FUSE(2A)28124VDC401327 1) AC Fuse (2A) : 2A is used as the

Pagina 26 - 4.6.2 VISUAL INDICATION

32 CHAPTER 6 INSTALLATION 6.1 POWER SUPPLY You should connect the Processor unit(BNW-51) to the Main power supply(AC 220V) using the AC cabl

Pagina 27

33 6.2.1 BRACKET MOUNTING Before installing, consider the display unit’s weight and search for the most convenient place for you.  Instal

Pagina 28 - 4.6.6 EMERGENCY CALL

34 audible alarm period can be changed from the setup menu. By using the jump pin (CN3: Tone OFF) from internal PCB, the 1st stage

Pagina 29

35 6.6 2ND & 3RD STAGE REMOTE AUDIBLE ALARM (ALARM/A~G) Install the alarm unit (BNW-52) in the officer’s room or the captain’s roo

Pagina 30 - POWER ALARMERRORAUTO TIMER

36 6.7 EXTERNAL FAILURE ALARM OUTPUT (ALARM/FAIL) Connect the failure alarm output to the external alarm. These two terminals are

Pagina 31

37 6.10 NMEA INPUT (NMEA/RXD) You can connect the digital equipment which can output the NMEA data (reset, alert etc). Also, when digital

Pagina 32

38 CHAPTER 7 INSTALLATION CONSIDERATION 7.1 GENERAL The following requirements are included in IMO resolution MSC.128(75) concerning the i

Pagina 33 - 6.2.2 FLUSH MOUNTING

39 CHAPTER 8 MOTION SENSOR 8.1 OPERATING MOTION SENSOR We have adapted Doppler radar principle so the sensor can detect the microwave (MW) an

Pagina 34

4 CAUTION 1. This BNWAS can be switched ON/OFF or settings can be changed with password, therefore only authorized person (captain) can change or s

Pagina 35

40 3) Insert the adapter below the bracket

Pagina 36

41  Check the operation after the installment Move around in the detective range after installation and check if the Green lamp (PIR), Brown lamp

Pagina 37

42 CHAPTER 9 TEST AFTER INSTALLATION Go through the check list below after the installing the equipment. No. Check list OK 1 Turn on the BNW-5

Pagina 38 - 7.1 GENERAL

43 CHAPTER 10 MAINTENANCE AND FAULT DIAGNOSIS 10.1 SYSTEM MAINTENANCE Constant maintenance is required to maintain the functionality of the equ

Pagina 39 - CHAPTER 8 MOTION SENSOR

44 2 BNW-50 does not turn on Check the AC or DC fuse. Check the power of AC input (220V) and DC input (24V) Check the power cable’s connection. 3 R

Pagina 40

45 CHAPTER 11 NMEA SENTENCE (IEC 61162-1) BNW-50 provides the interface such as IEC 61162-1 ALR, EVE…etc with the message below. SETTINGS : Bi

Pagina 41

46 11.4 GLL – Geographic position This sentence is a primary source of position information for the transponder when connected to

Pagina 42

47 CHAPTER 12 PACKING LIST 12.1 BNW-50 (STANDARD) BNW-50(Display Unit Desktop) NO. Item External Feature STANDARD Q’ty CHK Remark BNW-50 1 D

Pagina 43 - Symptoms Solutions

48 2A/250V[20mmX5mm] 7 FUSE CODE NO. 527-2002-1Q 2 AC POWER 5A/250V[20mmX5mm] 8 FUSE CODE NO. 527-2005-1Q 2 DC Power 12.3 BNW-52 FLUSH

Pagina 44

49 12.6 BNW-52W WATERTIGHT TYPE (STANDARD) 12.7 BNW-52 DESK TYPE (OPTION) BNW-52(Reset unit desktop) NO. Item External Feature STANDARD Q’ty

Pagina 45

5 ---- CONTENTS ---- CHAPTER 1 ABOUT BNWAS ...

Pagina 46 - 11.6 ZDA – Time and date

50 BNW-B(Desk type bracket) BNW-B 2 Bracket CODE NO. E02-1811-01 1 BNW-B-A(Desk type bracket installation accessory) M3X6 STS304 3 Bolt COD

Pagina 47 - Proc essor Unit

51 CHAPTER 13 DIAGRAMS 13.1 INTERCONNECTION DIAGRAM Ext Alarm1 PORTWatertightProcessor UnitDisplay UnitMotion SensorINTERCONNECTION DIAGRAMmax.

Pagina 48 - Alarm unit

52 13.2 INSTALLATION DIAGRAM ( EXAMPLE-1 ) 1SLDDISPLAYIN/OUT2 3 4TXD24VRXD212024VGNDALARME191824VGNDALARMD171624VGNDALARMC151424VGNDALARMB3130INP

Pagina 49

53 13.3 INSTALLATION DIAGRAM ( EXAMPLE-2 ) : Z8-2M-05A CABLE ASS'Y.: 6p shield(>UL2464-6C-24AWG): 2p shield(>UL2464-2C-20AWG): 3p shiel

Pagina 50

54 13.4 INSTALLATION DIAGRAM ( EXAMPLE-3 ) 1SLDDISPLAYIN/OUT2 3 4TXD24VRXD212024VGNDALARME191824VGNDALARMD171624VGNDALARMC151424VGNDALARMB7612VRE

Pagina 51 - CHAPTER 13 DIAGRAMS

55 13.5 BNW-50 OUTLINE DRAWING 12AB345 6CDEMENUESCEMG RES7 8 967134258

Pagina 52 - PROCESS UNIT

56 13.6 BNW-51 OUTLINE DRAWING 220±1210±1198±1ALARMCBridge Navigational Watch Alarm SystemA1BCAUTOPOWER ERROR ALARM TIMERProcessor UnitBNW-5123 4

Pagina 53

57 13.7 BNW-52 FLUSH TYPE OUTLINE DRAWING BNW-52Reset unitA123 4 5 6 7 8 9BC108SAMYUNGResetto resetPush button126±1105.5ED29.7±126.24-Ø3.390±17666

Pagina 54

58 13.8 BNW-53 FLUSH TYPE OUTLINE DRAWING 12A345 6BCSAMYUNGto bridgeAssistanceAlarm unitBNW-53108126±17 8 990±176664-Ø3.3ED105.529 7±126 2

Pagina 55

59 13.9 BNW-52W WATERTIGHT TYPE OUTLINE DRAWING to resetAB1 2SAMYUNG3 4Push buttonResetReset unitBNW-525 6127±1178±17 8 9CDE22±1175±192.5±1

Pagina 56 - Processor Unit

6 4.6 OPERATIONAL DESCRIPTION ...

Pagina 57 - Reset unit

60 13.10 BNW-B FLUSH TYPE OUTLINE DRAWING (BNW-52,53) 66±11 2A3 4 5 6BC4-M3TAP4-Ø3,5Ø3554±17 8 976.6±190±1ED90±1108.2±1114±11.2±0.138±113±1

Pagina 58

61 13.11 MOTION SENSOR(DND-300M) OUTLINE DRAWING 1 32 4ABCDE122.8±15 6 7 8 958±1 79±1

Pagina 59

62 CHAPTER 14 WARRANTY INFORMATION Thank you for purchasing SAMYUNG ENC LTD’s BNW-50. This manual includes the proper way of operat

Pagina 60

7 CHAPTER 10 MAINTENANCE AND FAULT DIAGNOSIS...43 10.1 SYSTEM MAIN

Pagina 61 - 58±1 79±1

8 CHAPTER 1 ABOUT BNWAS The purpose of a bridge navigational watch alarm system is to monitor the bridge activity and detect operator disability

Pagina 62

9 CHAPTER 2 OPERATION OF BNWAS This BNW-50’s setting is only adjustable by using password, therefore only authorized person (captain)